GA010系列 10瓦 3KVac隔離電壓 穩壓輸出 交流對直流電源轉換器

產品描述

功能&特點


  • 通用輸入電壓 90~264VAC。

  • 效率高達82%。

  • 短路/過載/過壓保護。

  • 塑膠外殼全封裝。

  • 內置輸入濾波器。

  • 產品保固3年。

  • 符合RoHS認證。




Specifications Typical At TA = 25°C, Nominal Input Voltage And Rated Output Current Unless Otherwise Specified


Part Number Output Wattage Output Voltage Output Current Ripple & Noise Efficiency
(W) (VDC) (mA) (mV) max (Note) (TYP %)
GA010-S03 10.0 3.3 3000 100 74
GA010-S05 10.0 5 2000 100 76
GA010-S12 12.0 12 1000 150 80
GA010-S15 12.0 15 800 150 80
GA010-S24 12.0 24 500 240 80
GA010-S48 12.0 48 250 240 82
GA010-D05 10.0 ±5 ±1000 100 75
GA010-D12 12.0 ±12 ±500 150 75
GA010-D15 12.0 ±15 ±400 150 75
GA010-D24 12.0 ±24 ±250 240 77
GA010-D0512 10.0 Vo1 = +5,
Vo2 = +12
Io1 = 1500,
Io2 = 200
100 (Vo1)
150 (Vo2)
74
GA010-D0515 10.0 Vo1 = +5,
Vo2 = +15
Io1 = 1400,
Io2 = 200
74
GA010-D0524 10.0 Vo1 = +5,
Vo2 = +24
Io1 = 1200,
Io2 = 200
75

Notes:
Ripple & noise is measured by using 20 MHz bandwidth, measured with a 47uf paralleled with a high-frequency 0.47uf capacitor arcoss each output by full load.



Input Specifications


Parameters Conditions Min Typ Max Units
Rated Input Voltage Vo, Io nom   100 ~ 240   Vac
Voltage Range Vo, Io nom AC in 90   264 Vac
DC in 120   370 Vdc
Line Frequency Vi nom, Io nom 47 50/60 63 Hz
Inrush Current Io nom Vi: 115VAC     10 A
Vi: 230VAC     20 A
Input Fuse VDE / UL / CCC FUSE 2.5A / 250V (Slow blow)


Output Specifications


Parameters Conditions Min Typ Max Units
Output Voltage Accuracy Vi nom, Io nom (Single output) 3.3V, 5V Models     ±3 %
12....48V Models     ±2
Dual Output     ±5 %
Minimum Load Vi nom Single Output Models 0     %
Dual Output Models
(each output)
20     %
Line Regulation Io nom, Vi min....Vi max   ±1   %
Load Regulation Io min~
Io nom
Single Output Models   ±2   %
Dual Output Models   ±5   %
Transient Recovery Time Vi nom, Io nom = ← → 0.5 Io nom   1000   us
Protection Over load Above 110% rated output power
Protection type: Recovers automatically after fault condition is removed
Short circuit Recovers automatically after fault condition is removed
Over Voltage
(Main Output)
120%-150% rated output Voltage
Protection type: Zener diode clamp


General Specifications


Parameters Conditions Min Typ Max Units
Switching Frequency Vi nom, Io nom   65   KHz
Isolation Voltage Input / Output 3KVac / 5mA / 5Secs
Isolation Resistance Input / Output, @500 Vdc 100    
Operating Temperature Operating at
Vi nom, Io nom
-20   +70
Derating Vi nom, Io nom
+51 to 71℃
    2 % / ℃
Storage Temperature Non Operational -40   +85
Relative Humidity Vi nom, Io nom     95 % RH
Safety Standards EN60950-1 approved
EMI Conduction & Radiation Compliance to EN55022
EMS Immunity Compliance to EN55024
Dimension L 63.50 x W 44.45 x H 19.05 mm
L 2.5 x W 1.75 x H 0.75 inches
Cooling Free air convection



Dimension






 Files Download      GA010-Series.pdf



Certification



產品詢價

GA003/GB003/GC003系列 3瓦 3KVac隔離電壓 穩壓輸出 交流對直流電源轉換器

GA005/GB005/GC005系列 5瓦 3KVac隔離電壓 穩壓輸出 交流對直流電源轉換器

GA5E系列 5瓦 3KVac隔離電壓 穩壓輸出 交流對直流電源轉換器

GA5A系列 5~6瓦 3KVac隔離電壓 穩壓輸出 交流對直流電源轉換器

GA007系列 7瓦 3KVac隔離電壓 穩壓輸出 交流對直流電源轉換器

GA10D系列 10~12瓦 4KVac隔離電壓 穩壓輸出 交流對直流電源轉換器

GA015系列 13~19瓦 3KVac隔離電壓 穩壓輸出 交流對直流電源轉換器

GA25D系列 20~27瓦 3KVac隔離電壓 穩壓輸出 交流對直流電源轉換器

GA025系列 25瓦 3KVac隔離電壓 穩壓輸出 交流對直流電源轉換器

GA025-SXX系列 14~25瓦 3KVac隔離電壓 穩壓輸出 交流對直流電源轉換器

GA030系列 26~48瓦 3KVac隔離電壓 穩壓輸出 交流對直流電源轉換器